Regular maintenance is essential to ensure the longevity and accuracy of your scale:
Turn the scale off. Hold down and turn the power switch back on to access the configuration menu.
| Feature | Specification Details | | :--- | :--- | | | 6kg / 15kg (30lb) / 30kg | | Display Resolution | 1/3,000, 1/6,000, or 1/7,500 | | Display Type | LCD with Backlight (16x134 Dots) | | Preset Keys | 96 or 120 programmable keys | | Memory Capacity | 2MB (Standard), expandable to 10MB (Max) | | Printing Speed | Up to 150mm/second (Label & Receipt) | | Paper Width | Label: 80mm / Receipt: 60mm | | Interface Options | RS232C, Ethernet 10/100 Base T, PS2 Keyboard | | Net Weight | 17.1 kg (approx. 37.7 lbs) |
: Connect the factory-supplied grounded AC cord into an isolated wall outlet. Avoid sharing an electrical circuit breaker with heavy inductive motor devices like commercial meat saws or walk-in freezers to eliminate line noise interference.
Specific guides for PLU setup and label formatting are available at The-Checkout-Tech . 🛠️ Key Technical Specifications The digi sm500 scale user manual exclusive
High-speed thermal printing (up to 150mm/s) with an 80mm wide label capability.
In this mode, use numeric keys to enter a PLU number or use preset keys for direct access.
: Scale IP addresses are configured using specific hex values (e.g., converting 192.168.168.XXX) and adjusted via system specifications like DIGI (TERAOKA) Maintenance & Troubleshooting Label/Receipt Change
Type the product name using the alpha-numeric keyboard overlay. Press to save the text. Enter the Unit Price. Press [PLU] . Regular maintenance is essential to ensure the longevity
If the scale is unresponsive or needs a full wipe, follow the Memory Initialization steps in the service manual (Section 4).
Indicates that a tare weight is currently subtracted from the display.
Ensure the thermal coating faces upward toward the printhead. Clean the elements with 99% Isopropyl alcohol.
: The standard model comes with 2MB of memory, expandable up to 10MB to accommodate extensive PLU (Price Look-Up) data, nutritional facts, and ingredient lists. press and hold the keys
The device supports extensive label customization. The maximum label size is 72mm (W) x 240mm (L). You can design label formats to include essential data like:
: 1. In Weighing Mode , press and hold the keys, then turn ON the Span Switch (a small switch typically located on the main PCB). 2. An access code prompt will appear. Enter the code [8][7][1][5] . 3. The scale will then display a prompt to calibrate the zero point. Ensure the weighing platter is completely empty. 4. Wait until the screen shows 'SET WEIGHT & PRT'. 5. Now, place a certified calibration weight that matches the scale’s maximum capacity onto the center of the platter (e.g., a 6kg weight for a 6kg scale). 6. The scale will automatically detect the weight and complete the calibration process. Once finished, press the Mode key to exit the calibration mode.
Slide the internal toggle switch to the (Calibration) position. Span Calibration Sequence